Light Permanent Magnet Flood Control Pump , Mobile Flood Control Pump In Stock Supply
Classification:
Sewage pump
Urban water supply
Key words:
Flood Control Pump
Sewage Pump
Pump In Stock Supply
Head Range: ~ 80 m
Hotline:
- Product Description
- Performance Parameter
- Installation Drawings
- Installation And Use
- Faults And Solutions
-
- Commodity name: Light Permanent Magnet Flood Control Pump , Mobile Flood Control Pump In Stock Supply
Flow Range: 100 ~ 1000 m ³/h<br> Head Range: ~ 80 m<br /></br><br /></br><br /></br><br /></br>
High-speed Axial Flow Pump with Permanent Magnet Synchronous Motor is one of our utility model patents, among a total of 20 utility model patents for permanent magnet synchronous motor driven pumps, including the patented invention of High-speed Deep Well Pump.The permanent magnet synchronous axial flow pump features high efficiency, light weight and compact size — its weight is only one quarter of that of conventional axial flow pumps. It also delivers large flow capacity and is easy to move. Equipped with hoses and quick flange couplings, it is ideal for flood drainage and emergency rescue, water pumping in subways, bridges and culverts, drainage for basements and parking lots, and other scenarios requiring flexible mobility. It is especially suitable for manual water drainage & irrigation or drainage via small vehicles.

This pump is integrated with automatic protection functions against overvoltage, overcurrent and phase loss. It will shut down automatically within one minute after pumping is finished, effectively protecting the motor winding from burnout. It is an intelligent axial flow pump.
Pump Unit
Our axial flow pump adopts a permanent magnet synchronous motor, belonging to our self-developed permanent magnet synchronous motor pump series. The impellers and flow passages of this high-efficiency axial flow pump are professionally designed by experts from hydraulic research institutes, delivering superior performance.
As one of our patented products supported by invention and utility model patents, the unit achieves an efficiency of up to 60%, ranking top in the industry and nearly 20% higher than many similar mainstream products. Third-party test reports issued by provincial and ministerial-level institutions are available.
We offer complete product ranges with flow rates of 200, 500, 800 and 1000 cubic meters per hour. We are a professional supplier with proprietary patented technology and full product specifications.
The pump is equipped with automatic protection against overheating, overcurrent and overload to prevent damage to motor windings. The impellers are precision cast from stainless steel, and the pump shaft is also made of stainless steel. The main body and pump casing are available in two material options: aluminum alloy and stainless steel. Cable terminals are protected by rubber sheaths and outer stainless steel springs for safe and reliable operation.The 8-inch water outlet interface uses the DN200mm 8-inch quick interface, the 10-inch water outlet interface uses the DN250mm 10-inch quick interface, and the 12-inch water outlet interface uses the DN300mm 12-inch quick interface, with buckle clamp, which is convenient to remove the external water belt. The cable comes standard with 20 meters and can be customized and lengthened.

Control System
The pump is equipped with a frequency converter, which displays frequency, voltage and current in real time. It supports automatic protection against overheating, overcurrent and overload, as well as automatic shutdown when running dry.
Optional remote control is available via 3G/4G network. Users can monitor data, start/stop the pump and adjust operating speed remotely through computers and mobile phones. Extra fees apply for the remote control configuration.
Control cabinets are available in one-drive-two and single-pump types, with protection grades of IP44 or IP54 for selection. Waterproof three-phase four-wire plugs and sockets are adopted as standard configuration to ensure operational safety and reliability.
For fixed drainage applications such as bridges, culverts, basements and parking lots, the system supports automatic operation. It will start automatically when the water level reaches the preset height, and switch to standby mode or shut down when the water level drops below the pump inlet.

After-sales Service
We provide 1-year warranty with free maintenance within the warranty period.For faults that cannot be resolved by phone consultation, our local distributors will offer on-site service. Within 500 kilometers nationwide, technicians will arrive on the same day; for locations over 500 kilometers away, service will be provided within two working days.
-
Flood control pump specification parameter table
Pump type
Model
Rated Flow
T/hRated Head
MMotor Power
KWOutlet Bore inch
Net Weight
KGOverall Dimension
mm
Remarks
High
Flow
Flood
Control
Pump
6SZQ250-8-11
250
8
11
6
21
250*280*570
8SZQ470-7-15
470
7
15
8
26/38
250*280*570
8SZQ480-8-18.5
480
8
18.5
8
29/39
250*280*570
8SZQ500-10-22
500
10
22
8
31/41
250*280*570
8SZQ500-12-27
500
12
27
8
32/42
250*280*570
10SZQ600-12-30
600
12
30
10
49
280*280*680
10SZQ800-10-37
800
10
37
10
50
280*280*680
12SZQ1000-8-37
1000
8
37
12
70
380*380*820
12SZQ1000-10-45
1000
10
45
12
78
380*380*820
12SZQ800-15-55
800
15
55
12
80
380*380*820
High
-head
Flood
Control
Pumpfor
Subways
6SZW100-50-22
100
50
22
6
31/41
230*230*580
6SZW150-32-22
150
32
22
6
31/41
230*230*580
6SZW200-45-37
200
45
37
6
42/49
280*280*700
6SZW200-55-45
200
55
45
6
44/51
280*280*700
8SZW300-18-22
300
18
22
8
31/41
230*230*580
8SZW300-23-30
300
23
30
8
32/43
230*230*580
8SZW300-30-37
300
30
37
8
43/50
280*280*700
8SZW300-40-55
300
40
55
8
76
380*380*740
8SZW300-50-75
300
50
75
8
83
380*380*740
8SZW400-20-37
400
20
37
8
51
280*280*700
8SZW400-30-55
400
30
55
8
78
380*380*780
8SZW400-40-75
400
40
75
8
83
380*380*800
8SZW400-50-95
400
50
95
8
86
380*380*800
8SZW400-60-110
400
60
110
8
125
420*420*1300
8SZW400-70-130
400
70
130
8
155
420*420*1500
8SZW400-80-150
400
80
150
8
210
450*450*1600
8SZW500-20-45
500
20
45
8
70
380*380*780
8SZW500-25-55
500
25
55
8
73
380*380*780
8SZW500-35-75
500
35
75
8
83
380*380*800
8SZW500-45-95
500
45
95
8
86
380*380*800
8SZW500-50-110
500
50
110
8
125
420*420*1300
8SZW500-60-130
500
60
130
8
155
420*420*1500
Dual-purpose pump
8SZQ-HL-22
500
32
22
8
45
280*280*580
10SZQ-HL-30
600
30
37
10
60
280*280*700
Bottom Suction
Pump
8SZQ500-9-22L
500
9
22
8
45
310*310*750
8SZQ600-10-30L
600
10
30
8
54
400*400*8500
10SZQ800-9-37L
800
9
37
10
56
400*400*850
Electrical cabinet weight: 15KW,31.6kg 22kw35.8kg,30kw44.6kg,37kw46.6kg,45kw62kg,55kw71kg.
Full set includes: Pump main unit (20m standard power cable), domestic frequency converter, complete stainless steel electrical cabinet, 1 set of quick couplings, 1 hose clamp, float assembly and other accessories.
-

-
Operating Instructions
The high-speed axial flow pump consists of two main parts: the pump body and the frequency converter. This manual mainly introduces the operation of the pump and basic use of the frequency converter, which is sufficient for regular operation. Professional parameter adjustment of the frequency converter shall be performed only by qualified personnel who have thoroughly read the dedicated manual for the frequency converter.

PRG和 JOG are function and programming keys. Unauthorized personnel are prohibited from operating these keys.Green RUN is the start key, or power-on key,《 《 《is the display toggle key,The red stop.The key is the stop key, or the shutdown key. The number displayed by the liquid crystal display by default is frequency. The frequency and speed are linear. The frequency is high and the speed is fast, while the frequency is low and the speed is low.Round knob and up and down keysUsed to adjust the frequency (or speed).

These four keys are in the lower part of the panel. The upper row is the power indicator and the running indicator respectively. The next row is the stunning start key and the red stop key respectively.
The variable frequency drive is generally debugged at the factory and does not need to be adjusted separately. Just press the on key or the start and stop keys on the operation panel, and do not press other keys. Do not move the internal wiring of the electrical cabinet easily. Check all the wiring terminals in the cabinet before starting up. If there is any looseness during transportation, tighten the wiring terminals one by one. If you need to adjust, you can only have professional knowledge of frequency converters, and you can adjust the parameters of the variable frequency drive only after carefully reading the variable frequency drive manual and this manual. Otherwise, the variable frequency variable frequency drive program may be confused and can no longer be used, or cause damage.
The three motor lines of the synchronous motor axial flow pump must be connected to the three terminals of the output U V T of the matching variable frequency drive, and cannot be directly connected to the power supply AC380V, otherwise the motor coil will be damaged and the pump will be scrapped. AC380VThe power supply is three-wire connected to the power input of the variable frequency driveR S T On. If it is a three-phase four-wire input of the power grid, do not connect the neutral line.At the incoming end, in case of unbalance of the zero line, there may be potential difference.The problem.
R
S
T
P-
P
P1
U
Words
P-,P, p1Empty, no wiring,One is the grounding wire. In principle, it is connected to the ground wire where it is located, not to the neutral wire of three-phase four-wire.
The frequency conversion controller is placed in the stainless steel electrical cabinet, and there are control circuits, cooling fans, circuit breakers, leakage protection, buttons, indicator lights, etc. The electrical cabinet has a rainproof function for outdoor use. In rainy days, attention should also be paid to spray, moisture and moisture.
The electrical cabinet is equipped with a power input socket and an output socket connected to the pump motor. There are notes below the socket for the input power end and the output pump end, which cannot be inserted incorrectly.
After the synchronous motor axial flow pump is equipped with a variable frequency drive, it has automatic protection functions such as overvoltage, overcurrent, overload, and overheating, and works with a wide voltage and keeps the speed synchronized. When there is no water at the pump inlet, the system will automatically detect and determine the entry into the protection program, and automatically shut down to avoid damage to the motor caused by no water cooling.
Each specification of the pump is matched with the corresponding variable frequency drive, the same specification (speed, flow, head and power) pump variable frequency drive can be exchanged, different specifications of the pump can not use the same variable frequency drive, because the motor parameters are not the same, some speed is not the same, can not be exchanged. If it is replaced incorrectly, it will cause damage to the variable frequency drive or pump.
The relationship between the flow, head and power of the axial flow pump is different from the hydraulic model of the centrifugal pump, and there is a big difference. When the axial flow pump used for low lift works at the same output frequency of the variable frequency drive, the lower the lift, the higher the flow rate, the lower the power consumption. If the lift at the work site is relatively low, the working frequency can be appropriately adjusted to set The highest frequency runs to increase the flow rate. However, the higher the lift is used, the greater the input power will be, which can reach 3 times the power at low lift. When the lift is high to a certain extent, when the input power will exceed the rated maximum allowable value, the variable frequency drive will have over-current protection and shut down. At this time, it is necessary to appropriately lower the working frequency of the variable frequency drive, reduce the rotating speed, and appropriately reduce the power to make the working current within the allowable range of the variable frequency drive, this allows the pump to operate normally. But this needs to be done under the operation of skilled staff with inverter expertise.
The rated lift of low-lift axial flow pump is generally 7-10 meters, which is below 15 meters, except for some up to 15 meters. If this low-lift axial flow pump is used for more than 15 meters, it is not appropriate, which will cause high power consumption and low efficiency. If the head is more than 15 meters, the flood control pump with high head should be selected. The pump head with high head is about 20-50 meters, and some are even higher.
In addition, the horizontal length of the water belt connected to the pump outlet is calculated according to the loss lift of 7-10 meters per 100 meters, that is to say, when the length of the water belt transported is 100 meters, it is equivalent to the working lift of 7-10 meters. When the long water belt is connected, if it is more than 200 meters, the actual working lift of the pump will exceed the rated lift, causing the variable frequency drive to stop for protection. At this time, the working current is within the allowable range of the variable frequency drive, so as to ensure the normal operation of the pump. Or re-elect to use high-lift flood pumps.
Usage Guidelines
1. This pump is designed for drainage. The submergence depth shall be kept between 1 m and 5 m. Before use, inspect the pump for integrity, check all joints for looseness, oil leakage and seepage. Examine the power cable for cuts or damage. Measure the insulation resistance with a megohmmeter: above 50 MΩ in cold state, and above 2 MΩ in hot state.
2. The pump allows a power voltage fluctuation of ±15%. The frequency converter ensures stable output. Excessively low voltage will increase input current and trigger overcurrent protection. Under such circumstances, switch to manual mode and lower the rotating speed to reduce current and power.
3. Equip the pump with an independent circuit breaker or switch. Connect the grounding terminals on the frequency converter and pump housing to reliable earth. The green-yellow bicolor wire in the pump cable is the grounding wire and must be grounded securely.
4. Never lift the pump by pulling the power cable, which may damage the insulation. If cable extension is required, the cross-sectional area of the extended wire shall be no less than that of the original cable. Seal all joints tightly with waterproof tape.
5. Before formal operation, power on the frequency converter and press the start key for a short trial run to check normal operation and correct rotation direction. Insufficient water output indicates wrong rotation direction. Swap any two of the three wires connecting the converter output terminals to the motor. Do not adjust the three power input wires of the converter, which will not change the rotation direction.
6. When lifting or lowering the pump, use ropes through the lifting ring instead of pulling the cable. Keep the pump at least 1 m above the water bottom to avoid sediment suction, which may damage the mechanical seal, impeller and other components.
7. For pumps suspended with float switches, monitor the water level closely during operation, especially in wells. Dry running is strictly prohibited, as it will burn out the motor and other parts. Do not place the pump into sludge at the bottom, otherwise poor heat dissipation will cause motor failure.
-
Pump Maintenance
1. After the electric pump accumulates 3,000 operating hours, replace wearing parts such as bearings, sealing rings, mechanical seals and cooling lubricant in a timely manner. Otherwise, component damage will result in greater losses.
2. If the electric pump is to be idle for a long period, clean and dry it completely. Repair peeling paint as needed, then store the pump properly in a ventilated and dry area.
Fault phenomenon
Cause
Solution
Motor Fails to Rotate
Incorrect wiring of power supply or frequency converter
Frequency converter activated fault protection
Pump impeller stuck, motor fails to start
Pump motor damaged
Frequency converter malfunctionCheck the wiring.
Inspect the circuit and frequency converter, and clear faults.
Find and eliminate the causes of impeller jamming.
Contact the maintenance department for faulty frequency converter, motor, bearings, windings and other components.
Pump delivers no water or insufficient flow
Incorrect rotation direction of impeller
Clogged inlet filter or impeller
Severely worn impeller
Partial damage to motor windings
Swap the wires connecting the frequency converter output to the pump.
Remove blockages and debris.
Replace the impeller or send it to the maintenance department for repair.
Troubleshooting & Solutions for Common Faults of Frequency Converter
No.
Fault code
Fault Type
Possible causes
Simple operation
countermeasures
0.
E-01
Output short circuit
1: Check whether the motor is short-circuited
2: Check whether the wire is damaged
3: slow down too fastP0.17
1: Replace the motor
2: Replace the motor
3: Increase the acceleration time1.
E-02
Accelerated overcurrent
Accelerate too fast
Inverter power is smallP0.16
Increase the acceleration time to increase the inverter power
2.
E-03
deceleration overcurrent
Deceleration too fast
Inverter power is smallP0.17
Increase the deceleration time to increase the inverter power
3.
E-04
Constant speed overcurrent
The motor load suddenly becomes larger
Check whether the motor load is abnormal
4.
E-05 E-06
acceleration overvoltage deceleration overvoltage
Input voltage too high deceleration too fast
Multimeter dial
750V output voltage P0.17Check input voltage increase deceleration time
5.
E-07
constant speed overvoltage
Protection voltage setting too small
Pd.11
Increase protection voltage
6.
E-08
Bus undervoltage
Input voltage too low
Multimeter dial
750V output voltageCheck input voltage
7.
E-09
Motor overload
The motor load suddenly becomes larger
Check whether the motor load is abnormal
8.
E-10
Inverter overload
Frequency converter is small
Increase converter power
9.
E-11
Input phase loss
Input voltage phase loss
Whether the output voltage is balanced when the multimeter is dialed to 750V
Check input voltage
10.
E-12
Output phase loss
Output voltage or motor phase loss
Multimeter dial
Is the 750V output voltage balanced or dial 200 ohms
Whether the resistance is balancedOutput voltage or motor phase loss
11.
E-13 E-14
Overheating of rectifier module Overheating of inverter module
Blocked air duct or damaged fan
The ambient temperature is too high
Control board wiring or plug-in looseDredge the air duct or more
Change the wind
Reduce the ambient temperature
Check and reconnectSerial Number
Fault code
Fault Name
Possible causes
Processing method
15
E015
Motor overload
1. Improper setting of motor parameters
2. Grid voltage is too low
3. The load is too large or stall occurs1. Re-calibrate the motor parameters
2. Check the grid voltage
3. Check the load16
E016
Module overheating
1. The ambient temperature is too high 2. The air duct is blocked
3. Fan is damaged
4. Module overheating device damage1. Improve the ambient temperature
2. Clean the air duct
3. Replace the fan
4. Seek technical support17
E017
Memory failure
Memory chip damage
Seek technical support
18
E018
External device failure
1. External input through multi-function digital terminal x
Fault signal
2. Misoperation of terminal1. Reset operation 2. Seek technical support
20
E022
Motor overheating fault
1. The motor temperature is too high
2. Motor temperature sensor fault1. Heat dissipation treatment of the motor
2. Check the motor temperature sensor and wiring21
E023
Contactor fault
1. Contactor is not normal
2. The driver board and power supply are not normal1. Replace the contactor 2. Seek technical support
22
E024
Communication failure
1. The upper computer is not normal
2. The communication line is not normal
3. Communication parameter group settings are incorrect1. Check the upper computer and connection
2. Check the communication line
3. Set the parameters correctly23
E055
Low frequency protection
The solar energy is insufficient and the output frequency is lower than HF. 04 Value
24
E056
Dry protection
Output current is less than HF. 06, and the output frequency is higher than HF. 31
If only the output current is detected, turn HF. 31 Set to 0.0Hz
25
E060
Light weak protection
Insufficient solar energy or low voltage
26
E065
Overload protection
The output current is greater than HF. 09 Value
This value is a percentage relative to P2.06
27
E070
Low power protection
Output power is less than HF. 12 value
28
E080
Full water protection
Normally open signal, valid when function #54 is on
Installed on top of water tower
29
E081
Empty water protection
Normally closed signal, valid when function #55 is disconnected
Installed at the bottom of water tower or well
Product Consulting
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!