What to do when the speed of a D-type horizontal multistage centrifugal pump is low

2025-07-15

Regarding the low speed of the D-type horizontal multi-stage centrifugal pump, the specific cause of the problem needs to be determined first, and corresponding solutions should be adopted for these causes. The following are some suggestions for low speed.

I. Diagnosing the Cause of the Problem

1. Check the power supply: Ensure that the power supply is stable and the voltage meets the pump's requirements. Low voltage may cause the motor speed to decrease.

2. Motor problems: Check if the motor is running normally. Motor failure or aging may lead to insufficient power, thus affecting the pump speed.

3. Fluid properties: Check if the fluid has excessively high viscosity or density, which will increase the pump load and cause the speed to decrease.

4. Internal blockage: Check if there is any blockage inside the pump, which will affect the pump's flow rate and speed.

II. Solutions

1. Power adjustment: Ensure the power supply is stable and adjust it to the appropriate voltage to meet the pump's power requirements.

2. Motor maintenance or replacement: If the motor is faulty or aging, it should be maintained or replaced with a new motor in time to ensure sufficient power output.

3. Adjust fluid properties: If the fluid properties are abnormal, consider adding a diluent or changing the type of fluid to reduce the load and increase the pump speed.

4. Clean blockages: Check and clean any blockages inside the pump to keep the fluid passage unobstructed.

III. Preventive Measures and Daily Maintenance

1. Regularly check the power supply: Ensure the power supply is stable and avoid voltage fluctuations affecting the pump.

2. Motor maintenance: Regularly check the motor's operating status and replace worn parts in time.

3. Fluid screening: Screen newly added fluids to prevent large particles from entering the pump.

4. Cleaning and maintenance: Regularly clean the inside of the pump to keep the fluid passage unobstructed, and check and replace worn seals and bearings.

IV. Safety Precautions

When dealing with pump speed problems, safety must be ensured. Avoid direct contact with the power supply and motor parts to prevent electric shock. During maintenance and repair, follow the safety regulations in the equipment operation manual.

In summary, for the problem of low speed in a D-type horizontal multi-stage centrifugal pump, the cause of the problem should be diagnosed first, and then the corresponding solutions should be adopted. At the same time, daily maintenance and safety preventive measures are also very important, which helps to extend the service life of the pump and improve its operating efficiency. If the problem is difficult to solve, it is recommended to seek help from professional technicians.

Contact Us

Free Hotline:0086-13307481676

Fixed telephone:0086-13307481676      

Mobile:0086-13307481676(WeChat)

E-mail:sales@sanchangpump.com