How to adjust the concentricity of a high-efficiency, energy-saving multi-stage pump
Category: Water pump knowledge
2025-08-01
High-efficiency energy-saving multi-stage pumps, as important fluid conveying equipment, their operating efficiency and stability largely depend on the concentricity between the rotor and stator inside the pump. Adjusting the concentricity can ensure the efficient operation of the pump, reduce energy consumption, and extend its service life. The following are methods for adjusting the concentricity of high-efficiency energy-saving multi-stage pumps.
I. Preliminary Preparations
Before starting the adjustment, a comprehensive inspection of the pump is required, including the wear condition of the rotor, the condition of the bearings, and the integrity of the sealing rings. Ensuring that all components meet operating requirements is the basis for adjusting concentricity.
II. Using Professional Tools
Use precision measuring tools such as dial indicators and micrometers to measure key parts of the pump. This allows for obtaining accurate concentricity data.
III. Adjustment Steps
1. Adjust bearing clearance: Ensure that the bearing clearance is appropriate, as this directly affects the operational stability and concentricity of the rotor.
2. Adjust rotor position: Adjust the position between the rotor and stator to achieve optimal concentricity.
3. Adjust bearings: If the bearings are severely worn, they need to be replaced promptly. At the same time, adjust the bearing preload to ensure stable operation of the rotor.
4. Adjust sealing rings: Wear on the sealing rings will affect the trajectory of the rotor, so they need to be adjusted or replaced.
IV. Dynamic Calibration
After adjustment, dynamic calibration is required. This involves starting the pump and observing its operating status. By measuring parameters such as vibration, noise, and temperature, it is possible to determine whether the concentricity has reached the optimal state.
V. Precautions
1. Ensure safety during the adjustment process to avoid accidental injury.
2. Be patient and careful during adjustment, as minor deviations will affect the pump's operating performance.
3. Unfamiliar personnel should not adjust the pump arbitrarily; professional personnel should perform the operation.
Adjusting the concentricity of a high-efficiency energy-saving multi-stage pump is a complex and important process. Through professional methods and tools, as well as meticulous operation, the efficient operation and stability of the pump can be ensured. This not only helps save energy but also extends the service life of the pump. In actual operation, safety and professionalism must be ensured.